Home»Producten»Vascular access - Infusion»Arterial catheters for Seldinger technique»Arterial Leader-Cath (PE)
Arterial Leader Cath
Leader Cath is a transparent catheter with radiopaque lines for arterial access, inserted using the Seldinger technique. It is supplied in a rigid blister pack containing:
- 1 introducer needle
- a PE catheter tapered at the distal end, with anti-kinking sleeve and winged hub for the fixation of the device.
- a straight metallic guidewire
- a polyurethane extension tube (10 cm long) with arterial Bionector
- 1 introducer needle
- a PE catheter tapered at the distal end, with anti-kinking sleeve and winged hub for the fixation of the device.
- a straight metallic guidewire
- a polyurethane extension tube (10 cm long) with arterial Bionector
Code |
Catheter
Int. Ø mm |
Catheter
Ext. Ø mm |
Catheter
Length cm |
Catheter
Gauge G |
Catheter
Ø Fr |
Catheter
Flow rate ml/min |
Catheter
Ø Fr |
Puncture needle
Int. Ø mm |
Puncture needle
Ext. Ø mm |
Puncture needle
G G |
Puncture needle
Length mm |
Guidewire
Ø mm |
Guidewire
Length cm |
Guidewire
Ø mm |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
115.079 | 0.6 | 0.9 | 8 | 20 | 3 | 24 | - | 0.6 | 0.9 | 20 | 38 | 0.53 | 200 | - |
115.090 | 0.6 | 0.9 | 8 | 20 | 3 | 24 | - | 0.6 | 0.9 | 20 | 38 | 0.53 | 20 | - |
115.092 | 0.6 | 0.9 | 2 | 20 | 3 | 33 | - | 0.6 | 0.9 | 20 | 38 | 0.53 | 20 | - |
115.094 | 0.6 | 0.9 | 4 | 20 | 3 | 30 | - | 0.6 | 0.9 | 20 | 38 | 0.53 | 20 | - |
115.096 | 0.6 | 0.9 | 6 | 20 | 3 | 27 | - | 0.6 | 0.9 | 20 | 38 | 0.53 | 20 | - |
115.11 | 0.8 | 1.2 | 10 | 18 | 4 | 24 | - | 0.8 | 1.1 | 19 | 52 | 0.71 | 30 | - |
115.118 | 0.8 | 1.2 | 8 | 18 | 4 | 43 | - | 0.8 | 1.1 | 19 | 52 | 0.71 | 30 | - |
115.12 | 0.8 | 1.2 | 18 | 18 | 4 | 34 | - | 0.8 | 1.1 | 19 | 68 | 0.71 | 46 | - |
115.15 | 1.0 | 1.5 | 18 | 17 | 4.5 | 67 | - | 1.1 | 1.4 | 17 | 70 | 0.9 | 46 | - |
115.17 | 1.2 | 1.7 | 18 | 16 | 5 | 109 | - | 1.4 | 1.7 | 16 | 70 | 1.1 | 46 | - |
115.798 | 0.6 | 0.9 | 8 | 20 | - | - | - | - | 0.9 | 20 | 32 | 0.5 | 20 | - |
115.802 | 0.6 | 0.9 | 8 | 20 | - | 24 | 3 | 0.6 | 0.9 | 20 | 38 | - | 20 | 0.53 |
115.803 | 0.6 | 0.9 | 8 | 20 | - | 24 | 3 | 0.6 | 0.9 | 20 | 38 | - | 20 | 0.53 |
Catheter | Puncture needle | Guidewire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code | Int. Ø mm |
Ext. Ø mm |
Length cm |
Gauge G |
Ø Fr |
Flow rate ml/min |
Ø Fr |
Int. Ø mm |
Ext. Ø mm |
G G |
Length mm |
Ø mm |
Length cm |
Ø mm |
|
115.079 | 0.6 | 0.9 | 8 | 20 | 3 | 24 | - | 0.6 | 0.9 | 20 | 38 | 0.53 | 200 | - | |
115.090 | 0.6 | 0.9 | 8 | 20 | 3 | 24 | - | 0.6 | 0.9 | 20 | 38 | 0.53 | 20 | - | |
115.092 | 0.6 | 0.9 | 2 | 20 | 3 | 33 | - | 0.6 | 0.9 | 20 | 38 | 0.53 | 20 | - | |
115.094 | 0.6 | 0.9 | 4 | 20 | 3 | 30 | - | 0.6 | 0.9 | 20 | 38 | 0.53 | 20 | - | |
115.096 | 0.6 | 0.9 | 6 | 20 | 3 | 27 | - | 0.6 | 0.9 | 20 | 38 | 0.53 | 20 | - | |
115.11 | 0.8 | 1.2 | 10 | 18 | 4 | 24 | - | 0.8 | 1.1 | 19 | 52 | 0.71 | 30 | - | |
115.118 | 0.8 | 1.2 | 8 | 18 | 4 | 43 | - | 0.8 | 1.1 | 19 | 52 | 0.71 | 30 | - | |
115.12 | 0.8 | 1.2 | 18 | 18 | 4 | 34 | - | 0.8 | 1.1 | 19 | 68 | 0.71 | 46 | - | |
115.15 | 1.0 | 1.5 | 18 | 17 | 4.5 | 67 | - | 1.1 | 1.4 | 17 | 70 | 0.9 | 46 | - | |
115.17 | 1.2 | 1.7 | 18 | 16 | 5 | 109 | - | 1.4 | 1.7 | 16 | 70 | 1.1 | 46 | - | |
115.798 | 0.6 | 0.9 | 8 | 20 | - | - | - | - | 0.9 | 20 | 32 | 0.5 | 20 | - | |
115.802 | 0.6 | 0.9 | 8 | 20 | - | 24 | 3 | 0.6 | 0.9 | 20 | 38 | - | 20 | 0.53 | |
115.803 | 0.6 | 0.9 | 8 | 20 | - | 24 | 3 | 0.6 | 0.9 | 20 | 38 | - | 20 | 0.53 |
- Contains Latex: No
- Contains DEHP: No
- Contains biogical or animal-based product: No
- Non-pyrogenic: Yes