Home»Producten»Vascular access - Infusion»Multilumen catheters for Seldinger technique »3 lumen catheters for Seldinger technique »Multicath + 3L
Multicath+ Kit 3 lumen, 7Fr, 15 cm, J voerdraad Nitinol met BLS
Multicath 3 + is a polyurethane triple-lumen catheter inserted in the jugular or subclavian vein using the Seldinger technique. The two references described here are for adult patients.
The needle of Multicath 3 + is fitted with a BLS valve (Blood Less System) avoiding the loss of blood during venipuncture and the risk of air embolism. Using the BLS valve implies no change in placement technique for the operator.
At the proximal end, each lumen of the catheter is connected to extension tubes of different lengths; besides each extension tube is marked "DISTAL", "MEDIAL 1" and "PROXIMAL" and includes a different coloured hub so as to identify easily the different infusion lines.
Kit Multicath 3 + is presented in a double packaging (supple blister + non woven table cover drape) including:
- 1 peelable drape for CVC
- 2 rectangular gallipots (60ml)
- 1 rounded gallipot (120 ml)
- 2 sponge sticks
- 15 gauze dressings 7.5 x 7.5 cm
- 1 hypodermic needle G21, L.40 mm
- 1 hypodermic needle G25, L.16 mm
- 1 Luer syringe 10 ml
- 1 metallic needle holder
- 1 transparent adhesive dressing film (Dermafilm)
In the non-woven drape, Multicath 3 + is presented in a rigid blister pack containing:
- 1 triple-lumen polyurethane catheter (totally radiopaque) with fixation wings and centimetric graduations from 5 cm from distal tip.
- 1 puncture needle 18G, 70 mm long with a pre-connected BLS valve. This valve avoids losses of blood during venipuncture and prevents any risk of air embolism. If the physician using the device prefers not to use the BLS valve, he only needs to remove it from the needle by unscrewing it.
- 1 Teflon-coated "J" Nitinol guidewire (particularly kink-resistant) with guide-advancer.
- 1 dilator, 10 cm long
- 3 Autoflush
- 3 clamps
- 1 supplementary fixation wing
- 1 scalpel
- 1 syringe 5 ml
- 1 adaptor for pressure transducer
The needle of Multicath 3 + is fitted with a BLS valve (Blood Less System) avoiding the loss of blood during venipuncture and the risk of air embolism. Using the BLS valve implies no change in placement technique for the operator.
At the proximal end, each lumen of the catheter is connected to extension tubes of different lengths; besides each extension tube is marked "DISTAL", "MEDIAL 1" and "PROXIMAL" and includes a different coloured hub so as to identify easily the different infusion lines.
Kit Multicath 3 + is presented in a double packaging (supple blister + non woven table cover drape) including:
- 1 peelable drape for CVC
- 2 rectangular gallipots (60ml)
- 1 rounded gallipot (120 ml)
- 2 sponge sticks
- 15 gauze dressings 7.5 x 7.5 cm
- 1 hypodermic needle G21, L.40 mm
- 1 hypodermic needle G25, L.16 mm
- 1 Luer syringe 10 ml
- 1 metallic needle holder
- 1 transparent adhesive dressing film (Dermafilm)
In the non-woven drape, Multicath 3 + is presented in a rigid blister pack containing:
- 1 triple-lumen polyurethane catheter (totally radiopaque) with fixation wings and centimetric graduations from 5 cm from distal tip.
- 1 puncture needle 18G, 70 mm long with a pre-connected BLS valve. This valve avoids losses of blood during venipuncture and prevents any risk of air embolism. If the physician using the device prefers not to use the BLS valve, he only needs to remove it from the needle by unscrewing it.
- 1 Teflon-coated "J" Nitinol guidewire (particularly kink-resistant) with guide-advancer.
- 1 dilator, 10 cm long
- 3 Autoflush
- 3 clamps
- 1 supplementary fixation wing
- 1 scalpel
- 1 syringe 5 ml
- 1 adaptor for pressure transducer
Code |
Catheter
Length cm |
Catheter
Ext. Ø mm |
Catheter
Ø Fr |
Distal lumen
Ø G |
Distal lumen
Flow rate ml/min |
Distal lumen
Prim. vol. ml |
Medial lumen
Prim. vol. ml |
Medial lumen
Flow rate ml/min |
Medial lumen
Ø G |
Proximal lumen
Ø G |
Proximal lumen
Flow rate ml/min |
Proximal lumen
Prim. vol. ml |
Puncture needle
G G |
Puncture needle
Length mm |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6208.2511 | 16 | 2.7 | 7.5 | 14 | 63 | 0.38 | 0.33 | 34 | 18 | 18 | 36 | 0.38 | 18 | 70 |
6209.2511 | 20 | 2.7 | 7.5 | 14 | 60 | 0.45 | 0.34 | 30 | 18 | 18 | 30 | 0.36 | 18 | 70 |
Catheter | Distal lumen | Medial lumen | Proximal lumen | Puncture needle | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code | Length cm |
Ext. Ø mm |
Ø Fr |
Ø G |
Flow rate ml/min |
Prim. vol. ml |
Prim. vol. ml |
Flow rate ml/min |
Ø G |
Ø G |
Flow rate ml/min |
Prim. vol. ml |
G G |
Length mm |
|
6208.2511 | 16 | 2.7 | 7.5 | 14 | 63 | 0.38 | 0.33 | 34 | 18 | 18 | 36 | 0.38 | 18 | 70 | |
6209.2511 | 20 | 2.7 | 7.5 | 14 | 60 | 0.45 | 0.34 | 30 | 18 | 18 | 30 | 0.36 | 18 | 70 |
- Contains Latex: No
- Contains DEHP: No
- Contains biogical or animal-based product: No
- Non-pyrogenic: Yes