Home»Producten» Enteral nutrition / Digestive tracts»Nutrisafe2 feeding systems for neonates»Accessories»Sampling devices
Nutrisafe 2 flacon perforator cap Ø 20 mm M
Vial access cap with Nutrisafe 2 connection for drug aspiration in a safe environment, avoiding the use of Luer devices or needles. This vial access cap is available for vial necks of 14 mm or 20 mm diameter.
Codes 821.112 and 821.122 have a female Nutrisafe 2 connector. They are connected to gravity feeding bottles. The vial acces cap is then connected to a Nutrisafe 2 extension tube which is connected to a Nutrisafe 2 feeding tube.
Codes 821.012 and 821.022 feature a male Nutrisafe 2 connector. These devices are used with Nutrisafe 2 syringes for drug sampling.
Quantity code 821.012 carton/box: 50/400
Quantity code 821.012 carton/box: 25/200
Code |
Compatibility
Ø flacon mm |
Cap
Ø mm |
Cannula
Length cm |
Cannula
Int. Ø mm |
Cannula
Ext. Ø mm |
Needle
Length mm |
Needle
Ext. Ø mm |
Needle
Int. Ø mm |
Spike
Length mm |
Spike
Int. Ø mm |
Spike
External diameter mm |
Spike
Priming volume ml |
---|---|---|---|---|---|---|---|---|---|---|---|---|
281.062 | - | - | - | - | - | - | - | - | 31.5 | 2.50 | 3.70 | 0.54 |
817.002 | - | - | - | - | - | 52 | 1.1 | 0.86 | - | - | - | - |
817.052 | - | - | 5 | 1.2 | 2.0 | - | - | - | - | - | - | - |
817.105 | - | - | 10 | 1.5 | 2.5 | - | - | - | - | - | - | - |
817.152 | - | - | 15 | 2.0 | 3.3 | - | - | - | - | - | - | - |
817.153 | - | - | 15 | 3.0 | 4.2 | - | - | - | - | - | - | - |
817.154 | - | - | 15 | 1.5 | 2.5 | - | - | - | - | - | - | - |
817.202 | - | - | 20 | 2.0 | 3.3 | - | - | - | - | - | - | - |
817.203 | - | - | 20 | 3.0 | 4.2 | - | - | - | - | - | - | - |
817.302 | - | - | 30 | 3.0 | 4.2 | - | - | - | - | - | - | - |
817.502 | - | - | 50 | 2.0 | 3.3 | - | - | - | - | - | - | - |
820.18 | - | 18 | - | - | - | - | - | - | - | - | - | - |
820.20 | - | 20 | - | - | - | - | - | - | - | - | - | - |
820.22 | - | 22 | - | - | - | - | - | - | - | - | - | - |
820.28 | - | 28 | - | - | - | - | - | - | - | - | - | - |
821.012 | 14 | - | - | - | - | - | - | - | - | - | - | 0.12 |
821.022 | 20 | - | - | - | - | - | - | - | - | - | - | 0.17 |
Compatibility | Cap | Cannula | Needle | Spike | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code | Ø flacon mm |
Ø mm |
Length cm |
Int. Ø mm |
Ext. Ø mm |
Length mm |
Ext. Ø mm |
Int. Ø mm |
Length mm |
Int. Ø mm |
External diameter mm |
Priming volume ml |
|
281.062 | - | - | - | - | - | - | - | - | 31.5 | 2.50 | 3.70 | 0.54 | |
817.002 | - | - | - | - | - | 52 | 1.1 | 0.86 | - | - | - | - | |
817.052 | - | - | 5 | 1.2 | 2.0 | - | - | - | - | - | - | - | |
817.105 | - | - | 10 | 1.5 | 2.5 | - | - | - | - | - | - | - | |
817.152 | - | - | 15 | 2.0 | 3.3 | - | - | - | - | - | - | - | |
817.153 | - | - | 15 | 3.0 | 4.2 | - | - | - | - | - | - | - | |
817.154 | - | - | 15 | 1.5 | 2.5 | - | - | - | - | - | - | - | |
817.202 | - | - | 20 | 2.0 | 3.3 | - | - | - | - | - | - | - | |
817.203 | - | - | 20 | 3.0 | 4.2 | - | - | - | - | - | - | - | |
817.302 | - | - | 30 | 3.0 | 4.2 | - | - | - | - | - | - | - | |
817.502 | - | - | 50 | 2.0 | 3.3 | - | - | - | - | - | - | - | |
820.18 | - | 18 | - | - | - | - | - | - | - | - | - | - | |
820.20 | - | 20 | - | - | - | - | - | - | - | - | - | - | |
820.22 | - | 22 | - | - | - | - | - | - | - | - | - | - | |
820.28 | - | 28 | - | - | - | - | - | - | - | - | - | - | |
821.012 | 14 | - | - | - | - | - | - | - | - | - | - | 0.12 | |
821.022 | 20 | - | - | - | - | - | - | - | - | - | - | 0.17 |
- Contains Latex: No
- Contains DEHP: No
- Contains biogical or animal-based product: No