Home»Producten»Vascular access - Infusion»Multilumen catheters for Seldinger technique »4 lumen catheters for Seldinger technique »Multicath + 4L / Kit Multicath + 4L
Multicath+ 4 lumen, 7Fr, 16 cm, J voerdraad Nitinol met BLS
Multicath 4 + is a polyurethane 4-lumen catheter inserted in the jugular or subclavian vein using the Seldinger technique.
Multicath 4 + is presented in a rigid blister pack containing:
- 1 4-lumen polyurethane catheter (totally radiopaque) with fixation wings and centimetric graduations from 9 cm from distal tip.
- 1 puncture needle 18G, 70 mm long with a pre-connected BLS valve. This valve avoids losses of blood during venipuncture and prevents any risk of air embolism. If the physician using the device prefers not to use the BLS valve, he only needs to remove it from the needle by unscrewing it.
- 1 Teflon-coated "J" Nitinol guidewire particularly kink-resistant with guide-advancer.
- 1 dilator, 10 cm long
- 4 injection caps
- 4 clamps
- 1 supplementary fixation wing
- 1 scalpel
- 1 syringe 5 ml
- 1 adaptor for pressure transducer
Multicath 4 + is presented in a rigid blister pack containing:
- 1 4-lumen polyurethane catheter (totally radiopaque) with fixation wings and centimetric graduations from 9 cm from distal tip.
- 1 puncture needle 18G, 70 mm long with a pre-connected BLS valve. This valve avoids losses of blood during venipuncture and prevents any risk of air embolism. If the physician using the device prefers not to use the BLS valve, he only needs to remove it from the needle by unscrewing it.
- 1 Teflon-coated "J" Nitinol guidewire particularly kink-resistant with guide-advancer.
- 1 dilator, 10 cm long
- 4 injection caps
- 4 clamps
- 1 supplementary fixation wing
- 1 scalpel
- 1 syringe 5 ml
- 1 adaptor for pressure transducer
Code |
Catheter
Length cm |
Catheter
Ext. Ø mm |
Catheter
Ø Fr |
Distal lumen
Ø G |
Distal lumen
Flow rate ml/min |
Distal lumen
Prim. vol. ml |
Medial lumen 1
Ø G |
Medial lumen 1
Flowrate ml/min |
Medial lumen 1
Prim. vol. ml |
Medial lumen 2
Ø G |
Medial lumen 2
Flowrate ml/min |
Medial lumen 2
Prim. vol. ml |
Proximal lumen
Ø G |
Proximal lumen
Flow rate ml/min |
Proximal lumen
Prim. vol. ml |
Puncture needle
Length mm |
Puncture needle
G G |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
158.1691 | 16 | 2.8 | 8.5 | 16 | 49 | 0.61 | 14 | 93 | 0.74 | 18 | 13 | 0.56 | 18 | 18 | 0.52 | 70 | 18 |
158.209 | 20 | 2.8 | 8.5 | 16 | 47 | 0.66 | 14 | 69 | 0.82 | 18 | 11 | 0.60 | 18 | 14 | 0.58 | - | - |
Catheter | Distal lumen | Medial lumen 1 | Medial lumen 2 | Proximal lumen | Puncture needle | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code | Length cm |
Ext. Ø mm |
Ø Fr |
Ø G |
Flow rate ml/min |
Prim. vol. ml |
Ø G |
Flowrate ml/min |
Prim. vol. ml |
Ø G |
Flowrate ml/min |
Prim. vol. ml |
Ø G |
Flow rate ml/min |
Prim. vol. ml |
Length mm |
G G |
|
158.1691 | 16 | 2.8 | 8.5 | 16 | 49 | 0.61 | 14 | 93 | 0.74 | 18 | 13 | 0.56 | 18 | 18 | 0.52 | 70 | 18 | |
158.209 | 20 | 2.8 | 8.5 | 16 | 47 | 0.66 | 14 | 69 | 0.82 | 18 | 11 | 0.60 | 18 | 14 | 0.58 | - | - |
- Contains Latex: No
- Contains DEHP: No
- Contains biogical or animal-based product: No
- Non-pyrogenic: Yes